Showing results: 136 - 150 of 169 items found.
-
M9157C -
Keysight Technologies
M9157C operates from DC to 26.5 GHz, providing a low-cost operation switching solution for measurement and automation of Automatic Test Equipment (ATE) systems without compromise in the RF performance. It is being used in applications such as ATE, RF communication and RF parametric measurements where a rugged switching module is needed for signal routing. Typical switching applications for multiport coaxial switches include signal routing to a single input to multiple instruments and routing of multiple input signals.
-
40-192A-012 -
Pickering Interfaces Ltd.
The 40-192A-012 is a PXI fault insertion switch using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
40-193A-001 -
Pickering Interfaces Ltd.
The 40-193A-001 is a 7-Channel Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
40-193A-002 -
Pickering Interfaces Ltd.
The 40-193A-002 is a 7-Channel Fault Insertion switch with two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
40-890-002 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-194A-001 -
Pickering Interfaces Ltd.
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
40-194A-002 -
Pickering Interfaces Ltd.
The 40-194A-002 is a 7-Channel Fault Insertion switch with two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
M9155CH40 -
Keysight Technologies
M9155CH40 PXI Hybrid Coaxial Switch: DC to 40 GHz, Dual SPDT, Unterminated
-
M9130A -
Keysight Technologies
The M9130A is a general purpose switch with 26 independent, single-pole, double-throw (Form C) switches in a single PXI module. This module can be used to cycle power to products under test, control indicator and status lights or actuate external power relays and solenoids. The armature relays can handle up to 60W power. When needed, these relays can handle up to 6A pulsed carry current. Choose from the durable connector block or standard cable connections.
-
M9161D -
Keysight Technologies
The Keysight M9161D PXI Dual SP4T solid state switch module provides an ultra-long cycle life, fast switching speed and high isolation, all within a single slot enclosure.
-
-
M9131A -
Keysight Technologies
The M9131A is a high-density, general purpose switch with 64 independent, single-pole, double-throw (Form C) switches in a single PXI module. This module can be used to cycle power to products under test, control indicator and status lights, or actuate external power relays and solenoids. The high-speed, long-life reed relays can handle 100 Vrms and 1 A, with up to 3 W maximum power. Choose from the durable connector block or standard cable connections.
-
-
34946A -
Keysight Technologies
The Keysight 34946A microwave switch for the 34980A Multifunction Switch/Measure Unit offers bi-directional switching for test signals from DC to 26.5 GHz. These switches provide excellent insertion loss, isolation, and VSWR specification. The microwave switches are configured as two independent 1x2 (SPDT) terminated switches on a single module. For general-purpose microwave switching applications, the module can be used to switch separate signal sources for a multi-band receiver/transmitter testing application.
-
784307-01 -
NI
PCI Express, Cabled Switch Device—The CPS‑8910 is designed for large multiple-input, multiple output (MIMO) expansion configurations and system control on the PXI platform or software defined radio devices. The CPS‑8910 provides two PCI Express upstream ports and eight downstream ports for seamless system expansion. You can connect the downstream ports to external devices, such as a Software Defined Radio Reconfigurable Device, to create large multichannel MIMO systems. You also can connect multiple CPS‑8910 switch boxes to a single PXI Express chassis to create massive MIMO systems with a Software Defined Radio Reconfigurable Device. The large data throughput capacity makes the CPS‑8910 an ideal data aggregator for massive MIMO systems. You can use the CPS‑8910 with copper or fiber-optic cables.